Cmd. Sub cmd. Data Description
00 See p. 13 Send the frequency data (transceive)
01 See p. 13 Send the mode data (transceive)
02
*
1
See p. 13 Read the band edge frequencies
03
*
1
See p. 13 Read the operating frequency
04
*
1
See p. 13 Read the operating mode
05
*
2
See p. 13 Set the operating frequency
06
*
2
See p. 13 Set the operating mode
07 Select the VFO mode
00 Select VFO A
( In the satellite mode, selects the VFO
mode.)
01 Select VFO B
(In the satellite mode, “FA” (NG) is returned.)
A0 Equalize VFO A and VFO B
B0 Exchange MAIN and SUB Bands
D0 Select the main band
D1 Select the sub band
D2* 00 Send/read main band selection
01 Send/read sub band selection
08
*
2
Select the Memory mode
0001 to 0099 Select the Memory channel (Including the
satellite mode)
(0001=M-CH01, 0099=M-CH99)
0100 to 0105 Select program scan edge channel
1A/1B to 3A/3B
( 0100/0101 (1A ch/1B ch),
0104/0105 (3A ch/3B ch))
0106, 0107 Select call channel C1/C2
(0106 (C1 ch), 0107 (C2 ch))
09 Memory write
0A Memory copy to VFO
0B Memory clear
0C
*
1
See p. 13 Read frequency offset
0D
*2
See p. 13 Send frequency offset
0E 00 Cancel the scan
01 Start a Programmed/memory scan
02 Start a Programmed scan
03 Start a
∂
F scan
12 Start a Fine programmed scan
13 Start a Fine
∂
F scan
22 Start a Memory scan
23 Start a Select memory scan
24 Start a Mode Select scan
Ax
*
2
(x=1 to 7)
Select
∂
F scan span
( x=1 (±5 kHz), x=2 (±10 kHz),
x=3 (±20 kHz), x=4 (±50 kHz),
x=5 (±100 kHz), x=6 (±500 kHz),
x=7 (±1 MHz))
B0
*
2
Clear the Select channel setting
B1
*
2
Set as select channel
( The previously set number by CI-V is set
after turning power ON, or “1” is selected if
no selection is performed.)
01 to 03 Set the channel as a Select channel
(01=SEL1, 02=SEL2, 03=SEL3)
B2
*
2
00 to 03 Set the Select memory scan channel
(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)
D0
*
2
Set Scan resume OFF
D3
*
2
Set Scan resume ON (Close&Delay)
0F
*1
00 Read Split OFF setting
01 Read Split ON setting
11 Read DUP– operation
12 Read DUP+ operation
13 Read DD Repeater Simplex mode (RPS)
00
*
2
Set Split function OFF
01
*
2
Set Split function ON
Cmd. Sub cmd. Data Description
0F
10
*
2
Set the simplex operation
11
*
2
Set DUP– operation
12
*
2
Set DUP+ operation
13
*
2
Set DD Repeater Simplex mode (RPS)
10* 00 to 11 Send/read the tuning step
( 00=OFF (10 Hz or 1 Hz),
01=100 Hz, 02=500 Hz, 03=1 kHz,
04=5 kHz, 05=6.25 kHz, 06=10 kHz,
07=12.5 kHz, 08=20 kHz, 09=25 kHz,
10=50 kHz, 11=100 kHz)
11* 00 Send/read attenuator OFF setting
10 Send/read 10 dB attenuator setting
13 00 Speech all data with voice synthesizer
(S meter level, frequency and mode)
01 Speech the operating frequency and S meter
level by voice synthesizer
02
Speech the operating mode by voice synthesizer
L The mode is announced after the ongoing
speech.
14* 01 0000 ~ 0255 Send/read the AF level
(0000=Minimum to 0255=Maximum)
02 0000 ~ 0255 Send/read the RF gain level
(0000=Minimum to 0255=Maximum)
03 0000 ~ 0255 Send/read the squelch level
(0000=Minimum to 0255=Maximum)
06 0000 ~ 0255 Send/read the NR level
(0000=0%, 0255=100%)
07 0000 ~ 0255 Send/read [TWIN PBT] (PBT1) position
( 0000=max. Counter Clockwise, 0128=center,
0255=max. Clockwise)
08 0000 ~ 0255 Send/read [TWIN PBT] (PBT2) position
( 0000=max. Counter Clockwise, 0128=center,
0255=max. Clockwise)
09 0000 ~ 0255 Send/read CW pitch (5 Hz steps)
( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz)
0A 0000 ~ 0255 Send/read RF power
( 0000=Minimum to 0255=Maximum)
0B 0000 ~ 0255 Send/read MIC gain
(0000=Minimum to 0255=Maximum)
0C 0000 ~ 0255 Send/read keying speed
(0000=6 WPM to 0255=48 WPM)
0D 0000 ~ 0255 Send/read Notch lter setting
( 0000=max. Counter Clockwise, 0128=center,
0255=max. Clockwise)
0E 0000 ~ 0255 Send/read the COMP level
(0000=0 to 0255=10)
0F 0000 ~ 0255 Send/read the Break-IN Delay setting
(0000=2.0 d to 0255=13.0 d)
12 0000 ~ 0255 Send/read NB level
(0000=0% to 0255=100%)
15 0000 ~ 0255 Send/read Monitor audio [MONI] level
(0000=0% to 0255=100%)
16 0000 ~ 0255 Send/read the VOX gain
(0000=0% to 0255=100%)
17 0000 ~ 0255 Send/read the Anti VOX gain
(0000=0% to 0255=100%)
19 0000 ~ 0255 Send/read LCD backlight brightness
(0000=0% to 0255=100%)
15
*
1
01 00 or 01 Read noise or S-meter squelch status
(00=Close, 01=Open)
02 0000 to 0255 Read S-meter level
(0000=S0, 0120=S9, 0241=S9+60 dB)
05 00 or 01 Read various squelch (tone squelch, and so
on) status
(00=Close, 01=Open)
07 00 or 01 Read the OVF status
( 00=OVF indicator is OFF, 01=OVF indicator is ON)
11 0000 ~ 0255 Read the PO meter level
(0000=0% to 0143=50% to 0213=100%)
D Command table
NOTE: Operation of some control dials overrides CI-V commands. If a control dial, such as the AF Volume dial that has
a mark on it, is rotated after sending a CI-V command, the command will be overwritten by the operation.
Remote control
4