5 - 1
SECTION 5 ADJUSTMENT PROCEDURE
5-1 PREPARATION
¤ REQUIRED EQUIPMENTS
EQUIPMENT GRADE AND RANGE EQUIPMENT GRADE AND RANGE
Cloning software
CS-F50V
CLONING SOFTWARE
(Revision 1.0 or later)
JIG cable
(Modifi ed OPC-
966C/UC)
(See the page 5-3)
RF power meter
(terminated type)
Measuring range : 0.1–10 W
Frequency range : 100–300 MHz
Impedance : 50
Ω
SWR : Less than 1.2 : 1
Standard signal
generator (SSG)
Frequency range : 0.1–300 MHz
Output level : 0.1 mV to 32 mV
(–127 to –17 dBm)
Frequency counter
Frequency range : 0.1–300 MHz
Frequency accuracy : ±1 ppm or better
Input level : Less than 1 mW
Oscilloscope
Frequency range : DC–20 MHz
Measuring range : 0.01–20 V
AC millivoltmeter Measuring range : 10 mV to 10 V
Modulation
Analyzer
Frequency range : 30–300 MHz
Measuring range : 0 to ±10 kHz
External speaker
Input impedance : 8
Ω
Capacity : More than 1 W
Audio generator
Frequency range : 300–3000 Hz
Output level : 1–500 mV
Attenuator
Power attenuation : 30 dB
Capacity : More than 10 W
¤ CLONING ADJUSTMENT CHANNELS
Before starting adjustment, clone adjustment frequencies and other conditions into the transceiver using CS-F50V
CLONING SOFTWARE as below.
• ADJUSTMENT CHANNELS
CAUTION!: BACK UP the originally programmed memory data in the transceiver before programming the adjustment frequen-
cies. When program the adjustment frequencies into the transceiver, the transceiver’s memory data will be overwrit-
ten and lose original memory data at the same time.
NOTE: FOR [EUR], [EUR-01] AND [EUR-02], when adjust “Devation” and “Modulation Balance” in the middle band, change the
bandwidth to “Middle” as below.