5 - 10
ADJUSTMENT
[ADJUST ITEM]
ADJUSTMENT CONDITION OPERATION VALUE
RECEIVE
SENSITIVITY
[BPF T1]
1•
Channel : 1-13
Connect a Standard Signal Generator to the
antenna connector.
Receiving
Put the cursor on the [BPF T1],
and push the return key.
(Automatic
adjustment)
[BPF T2] 2 Put the cursor on the [BPF T2],
and push the return key.
CONVENIENT:
RECEIVE SENSITIVITY can be adjusted totally. Put the cursor on the [BPF ALL], and push the return key.
5-4 RECEIVE ADJUSTMENT
Select an adjustment item using [
] / [
] keys, then set to the specifi ed value using [
] / [
] keys on the connected PC’s keyboard.
STANDARD SIGNAL GENERATOR
(1–300 MHz)
SETTING;
Modulation : 1 kHz
Deviation : 3.5 kHz
Level : +20 dBµ