5 - 5
ADJUSTMENT
[ADJUST ITEM]
ADJUSTMENT CONDITION OPERATION VALUE
REFERENCE
FREQUENCY
[REF]
1 • Channel : 1-2
Connect an RF Power Meter to the
antenna connector.
Transmitting
Loosely couple a Frequency Counter to
the antenna connector.
174.000 MHz
•
•
(Loose Coupling)
FREQUENCY COUNTER
(0.1–300 MHz)
RF POWER METER
(10 W/50 Ω)
5-2 FREQUENCY ADJUSTMENT (continued)
Select an adjustment item using [
↑
] / [
↓
] keys, then set to the specifi ed value using [
←
] / [
→
] keys on the connected PC’s keyboard.