6-4 RECEIVE ADJUSTMENT (continued)
1) Select an adjustment item using cursor or [
↑
] / [
↓
] keys of the PC’s keyboard.
2) Set or modify the adjustment value as specifi ed using [
←
] / [
→
] keys of the PC’s keyboard, then push the [ENTER] key.
ADJUSTMENT ADJUSTMENT CONDITION OPERATION
ADJUSTMENT
ITEM/POINT
VALUE
S-METER
-Preparation-
NOTE: "RECEIVE SENSITIVITY" MUST be adjusted before "S-METER." When "RECEIVE SENSITIVITY" is re-
adjusted, "S-METER" MUST be re-adjusted too.
1• Connect an SSG to the RX
antenna connector.
• Set the SSG as;
Frequency : 173.900 MHz
Modulation : 1 kHz
Deviation : 3.5 kHz
––
-Adjust-
(S3 level)
2 • CH. : 1-29
• Receiving
1) Set the SSG as;
Level : +23 dB
μ
2) Select the item [RSSI S3 Level],
then push the [ENTER] key to store
the adjust value.
[RSSI S3 Level]
(Automatic
adjustment)
(S1 level) 3 • CH. : 1-29
• Receiving
1) Set the SSG as;
Level : –7 dB
μ
2) Select the item [RSSI S1 Level],
then push the [ENTER] key, to store
the adjust value.
[RSSI S1 Level]
(Automatic
adjustment)
SQUELCH 1 • CH. : 1-30
• Receiving
• Set the item [SQL Level] to "2." [SQL Level] "2"
2
• Set the preset adjustment value on the
adjustment utility window.
[SQL]
"35"
6 - 9
(Replacement page)