61
7
DSC OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D Receiving a Polling Request call/Test Call
[Example]: Receiving a Polling Request call.
When a Polling Request call is received:
The alarm sounds for 2 minutes.
“RCVD POLLING REQUEST” is displayed. The backlight
blinks for 2 minutes.
q Push [ALARM OFF] to stop the alarm and the blinking
backlight.
Even if you do not push [ALARM OFF], the alarm stops after 2
minutes, and then the screen in step w is displayed.
w Push a softkey to select your desired action.
[IGN]
Push to ignore the Call and return to the normal operat-
ing mode.
The transceiver exits the DSC mode.
continues to blink and the Call is stored in the Received
Call Log.
[INFO]
Push to display the Received call information. (p. 63)
[ACK]
Push to display the “POLLING REPLY” screen to reply
to the Call. (p. 53)
When “POSITION ACK” or “TEST ACK” is set to “Auto TX,
the transceiver automatically replies to the Call. In that
case, both the TX and RX calls are stored in the Transmit-
ted and Received Call Logs.