5 - 6
SOFTWARE ADJUSTMENT (continued)
ADJUSTMENT
ITEM
ADJUSTMENT CONDITION DISPLAY OPERATION
SENSITIVITY
[Tr]
1 • Operating freq. : 118.100 MHz
Connect an SSG to the antenna
connector and set as :
Level : 1 µV* (–107dBm)
Modulation : 1 kHz
Deviation : 3.5 kHz
• Receiving
• Push [BAND].
2 • Operating freq. : 146.100 MHz
• Receiving
• Push [BAND].
3 • Operating freq. : 160.100 MHz
• Receiving
• Push [BAND].
4 • Operating freq. : 173.900 MHz
• Receiving
• Push [BAND].
5 • Operating freq. : 230.100 MHz
• Receiving
• Push [BAND].
6 • Operating freq. : 260.100 MHz
• Receiving
• Push [BAND].
7 • Operating freq. : 380.100 MHz
• Receiving
• Push [BAND].
8 • Operating freq. : 399.900 MHz
• Receiving
• Push [BAND].
9 • Operating freq. : 400.100 MHz
• Receiving
• Push [BAND].
10 • Operating freq. : 429.900 MHz
• Receiving
• Push [BAND].
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.