¤ REQUIRED INSTRUMENTS
INSTRUMENTS SPECIFIDATION INSTRUMENTS SPECIFIDATION
DC Cable (Supplied with transceiver) JIG cable
(See the illust below)
Power Supply
Output voltages : 13.8 V DC
and 12.0 V DC
Current capacity : More than 15 A
Multimeter
Input impedance : 50 k
Ω
Measuring range : 0.1–20V/0.01–5 A
RF Power Meter
(terminated type)
Measuring range : 0.1–60 W
Except [TPE]
0.1–30 W [TPE]
Frequency range : 100–600 MHz
Impedance : 50
Ω
SWR : Less than 1.2 : 1
Standard Signal
Generator (SSG)
Frequency range : 0.1–1200 MHz
Output level : 0.04 µV to 32 mV
(–28 dBu to 90 dBu)
Terminator Impedance : 50
Ω
Frequency counter
Frequency range : 0.1–600 MHz
Frequency accuracy :
±0.1 ppm or better
Input level : Less than 1 mW
AC Millivoltmeter Measuring range : 10 mV to 10 V
Attenuator
Power attenuation : 40 dB
Capacity : More than 100 W
Modulation
Analyzer
Frequency range : 30–600 MHz
Measuring range : 0 to ±10 kHz
Audio generator
Frequency range : 300–3000 Hz
Output level : 1–500 mV
M JIG CABLE
8-pin modular jack
q
i
u
ytre
w
q
w
e
r
t
y
u
i
8V
MICU/D
EXTMIC
PTT
MICE
MIC
GND
MICIN
y (MIC)
w (MICU/D)
u (GND)
r (PTT)
u (GND)
t (MICE)
AUDIO GENERATOR
(300–3000 Hz/1–500 mV)
+−
22 k
+−
AC MILLIVOLTMETER
(10 mV to 10 V)
PTT
To [ MICROPHONE CONNECTOR]
SECTION 5. ADJUSTMENT PROCEDURE
5 - 1
5-1 PREPARATION