5 - 7
5-6 RECEIVE SENSITIVITY ADJUSTMENT
1) Select an adjustment item using [VFO/MHz] / [M/CALL].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION VALUE
RECEIVE
SENSITIVITY
[LT1]
1• Connect an SSG to the antenna connector and set as;
Modulation : 1 kHz
Deviation : 3.5 kHz
Level : 0 dBµ (–107 dBm)
†
Push [BAND]
(Automatic
adjustment)
2 • Set the SSG as;
Frequency : (Displayed on the function display)
[MT1]
3 • Set the SSG as;
Frequency : (Displayed on the function display)
[HT1]
4 • Set the SSG as;
Frequency : (Displayed on the function display)
[LT2]
5 • Set the SSG as;
Frequency : (Displayed on the function display)
[MT2]
6 • Set the SSG as;
Frequency : (Displayed on the function display)
[HT2]
7 • Set the SSG as;
Frequency : (Displayed on the function display)
[LT3]
8 • Set the SSG as;
Frequency : (Displayed on the function display)
[MT3]
9 • Set the SSG as;
Frequency : (Displayed on the function display)
[HT3]
10 • Set the SSG as;
Frequency : (Displayed on the function display)
[UT3]
11 • Set the SSG as;
Frequency : (Displayed on the function display)
[LT4]
12 • Set the SSG as;
Frequency : (Displayed on the function display)
[MT4]
13 • Set the SSG as;
Frequency : (Displayed on the function display)
[HT4]
14 • Set the SSG as;
Frequency : (Displayed on the function display)
[UT4]
15 • Set the SSG as;
Frequency : (Displayed on the function display)
[LT5]
16 • Set the SSG as;
Frequency : (Displayed on the function display)
[MT5]
17 • Set the SSG as;
Frequency : (Displayed on the function display)
[HT5]
18 • Set the SSG as;
Frequency : (Displayed on the function display)
†
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.