11
32
SERVICE MAN MENU
■ Service man menu
To open the “SERVICE MAN” menu.
Push [MENU]/[ ] several times to show the
“SERVICE MAN” menu.
■ Select the language
Menu screens can be displayed in 2 different
languages.
Selectable languages; ENGLISH, (CHINESE)
After opening the “SERVICE MAN” menu;
q Push [Ù] to show the present language.
w Push [
Ω≈
] to select desired language, then push
[Ú] to continue the setting.
e Push [MENU]/[ ] to exit the “SERVICE MAN”
menu.
D TIMING ADJ.
• Corrects the distance.
D HDG ADJ.
• Adjusts the electronic heading line adjustment.
D SPD ADJ.
• Enter the pulse rate of the speed sensor.
D RANGE
•
1
⁄8,
1
⁄4,
1
⁄2,
3
⁄4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36,
48*, 64
†
, 72
†
: Choose the selectable screen range.
*MR-1000TII/TIII
†
MR-1000TIII only
D SETUP MEMORY
•The present setting value is displayed by pushing [
≈
],
then select the desired item from “RECALL” and
“SAVE” using with [Ú].
q Push [
≈
] to display “RECALL” and “SAVE”.
w Push [ÙÚ] to select “RECALL” or “SAVE”.
e Push [
≈
].
•“SURE ?” is displayed.
r Push [
≈
] to perform.
t Push [
Ω
]
to cancel
.
• When recall is performed without saving a setup, it
will become an initial value at the time of factory
shipments.
D Other readouts
• OUTPUT VOLTAGE
: Shows the voltage level for the
scanner unit from the display unit.
• HV (High voltage) : Shows the voltage level in the
high-voltage unit in the scanner
unit.
• MONITOR : Shows the voltage level for
checking the receiver unit opera-
tion.
• HEATER : Shows the heater current.
• MG :Shows the current level for the
Magnetron.
• TX TIME : Shows the total transmitted time.