29
Code LCM Display Function Description Accessibility
123
Sensor Inventory
Adjustment
Detect Tube Inventory
-Only MDB for TWD
、
SGD
、
MYR
、
THB
、
CNY
Default Definition
N/A
Detect tube inventory and overwrite tube count data.
LCM Descriptions
Press the Manual button.
Use A / C to scroll to EZ code 123.
Press F to enter.
Press D to cancel.
Press F to read the coin inventory and save the inventory amount.
The changer displays message as left when tube count has been overwritten
successfully, then back to main configuration screen automatically.
Manual to exit.
Code LCM Display Function Description Accessibility
124
Reserved Coin Set Reserved Coin Function
Default Definition
ON
Setup reserved coin function to ON or OFF.
Reserved Coin ON: Changer will not pay out to last coin among operation,
specific number of coins will reserve inside tubes, around 4 coins. The
reserved coin number depends on different region.
Reserved Coin OFF: Changer pays out to last coin in tubes.
LCM Descriptions
Press the Manual button.
Use A / C to scroll to EZ code 124.
Press F to enter.
Changer displays current setting.
Press F to change reserved coin setting to ON or OFF.
When finished, press Manual button to exit.
Manual to exit.
Scan Inventory?
D=NO, F=YES
Sensor Inventory
Ad