SECTION 3 - SERVICING
3.25 CH WATER PRESSURE SWITCH REPLACEMENT
1. Refer to Section 3.9.
2. Drain the boiler. Refer to Section 3.20.
3. Pull off the two electrical connections.
4. Using a suitable tool, pull out the metal
retaining clip.
5. Carefully withdraw the pressure switch.
6. Fit the new pressure switch and re-
assemble in reverse order.
7. Rell the boiler.
8. Check operation of the boiler. Refer to
Sections 2.25 & 2.26.
1. Refer to Section 3.9.
2. Drain down the boiler. Refer to Section 3.20.
3. Unplug the electrical lead.
4. Unscrew the thermistor (to facilitate removal a
13mm socket spanner should be used).
5. Fit the new thermistor using the sealing
washer provided.
6. Reassemble in the reverse order.
7. Rell the boiler. Refer to Section 2.19.
8. Check the operation of the boiler. Refer to
Sections 2.25 & 2.26.