EasyManua.ls Logo

Ideal Heating LOGIC+ SYSTEM S30 - User Manual

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
specication that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Hunt Heating.
December 2020
UIN 225326 A03
INSTALLATION
& SERVICING
LOGIC+ SYSTEM
S18 S30
HEATING

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ideal Heating LOGIC+ SYSTEM S30 and is the answer not in the manual?

Summary

SECTION 1 - GENERAL

1.3 SAFE HANDLING

Precautions and techniques for safe handling of the boiler during installation.

1.5 SAFETY

Guidance on safety regulations and precautions for boiler installation.

1.8 GAS SUPPLY

Requirements and safety for the gas supply connection to the boiler.

1.9 FLUE INSTALLATION

Instructions for the correct installation of the boiler's flue system.

1.14 ELECTRICAL SUPPLY

Details on electrical supply requirements, earthing, and connection precautions.

SECTION 2 - INSTALLATION

2.1 INTERNAL BOILER ASSEMBLY - Exploded View

Diagram and parts list for the internal boiler assembly.

2.2 EXTERNAL BOILER ASSEMBLY - Exploded View

Diagram and parts list for the external boiler assembly.

2.8 FITTING THE WALL MOUNTING BRACKET - INTERNAL BOILER

Procedure for fitting the wall mounting bracket for internal boilers.

2.13 DETERMINING THE FLUE LENGTH

Guidelines for calculating the correct flue length based on boiler model and configuration.

2.20 ELECTRICAL CONNECTIONS

Guidelines for safe electrical connections, including earthing and supply.

2.23 WIRING DIAGRAM

Schematic diagram illustrating the boiler's internal wiring connections.

2.24 COMMISSIONING AND TESTING

Steps for commissioning and testing the boiler after installation.

2.25 INITIAL LIGHTING

Procedure for the initial startup and lighting of the boiler.

SECTION 3 - SERVICING

3.9 REPLACEMENT OF COMPONENTS

General guidelines and important notes for replacing boiler components.

3.19 PCB REPLACEMENT

Procedure for replacing the Printed Circuit Board (PCB).

SECTION 4 - FAULT FINDING

4.1 FAULT FINDING CHART MAIN MENU

Overview of fault codes and their corresponding troubleshooting sections.

4.2 L1 - FLOW TEMPERATURE OVERHEAT LOCKOUT OR NO WATER FLOW LOCKOUT

Troubleshooting steps for L1 fault code related to overheat or no water flow.

4.3 L2 - IGNITION LOCKOUT

Troubleshooting steps for L2 fault code related to ignition failure.

4.4 L6 - FALSE FLAME LOCKOUT

Troubleshooting steps for L6 fault code related to false flame detection.

4.5 F1 - LOW WATER PRESSURE

Troubleshooting steps for F1 fault code related to low water pressure.

4.6 F2 OR Fn OR Ln - FLAME LOSS

Troubleshooting steps for F2/Fn/Ln fault codes related to flame loss.

4.7 F3 - FAN FAULT

Troubleshooting steps for F3 fault code related to fan malfunction.

4.8 L4 OR F4 - CONTROL; NO FLOW THERMISTOR FAULT

Troubleshooting steps for L4/F4 fault codes for thermistor issues.

4.9 F5 OR L5 - RETURN THERMISTOR FAULT

Troubleshooting steps for F5/L5 fault codes for return thermistor issues.

4.10 F6 - OUTSIDE SENSOR FAULT

Troubleshooting steps for F6 fault code related to outside sensor failure.

4.11 NO CH OPERATION

Troubleshooting steps for issues with no central heating operation.

4.12 NO DISPLAY

Troubleshooting steps for issues with no display on the boiler.

4.13 NO HW

Troubleshooting steps for issues with no hot water (HW).

SECTION 5 - SPARE PARTS

6 COMMISSIONING & SERVICING

GAS BOILER SYSTEM COMMISSIONING CHECKLIST & WARRANTY VALIDATION RECORD

Checklist for commissioning the boiler and validating the warranty.

SERVICE & INTERIM BOILER WORK RECORD

FLOWCHART FOR CO LEVEL AND COMBUSTION RATIO CHECK ON COMMISSIONING A CONDENSING BOILER

Ideal Heating LOGIC+ SYSTEM S30 Specifications

General IconGeneral
TypeSystem Boiler
Output30 kW
ERP RatingA
MountingWall-mounted
FuelNatural Gas
Width395 mm
Height700 mm
Depth278 mm
Warranty7 years
Heating Flow Temperature Range30-80°C
Maximum Working Pressure3 bar