Page 17
*Press the Blue button to enter AC Current function
AC Current Test: Model 61-481 and 61-482
Range Source Frequency Reading
40mA 37.00mA 50Hz 36.21 to 37.79
40mA 37.00mA 1KHz 36.21 to 37.79
400mA 370.0mA 50Hz 362.1 to 377.9
400mA 370.0mA 1KHz 362.1 to 377.9
1A .90A 50Hz 0.83 to .97
1A .90A 1KHz 0.83 to .97
10A 9.0A 50Hz 8.73 to 9.27
10A 9.0A 1KHz 8.73 to 9.27
Resistance Test: Model 61-480
Range Source Reading
300Ω 180Ω
177.8 to 182.2
3KΩ 1.800KΩ
1.785 to 1.815
30KΩ 18.00KΩ
17.85 to 18.15
300KΩ 180.0KΩ
178.5 to 181.5
3MΩ 1.800MΩ
1.779 to 1.821
30MΩ 29.00MΩ
28.37 to 29.63
*Lead resistance on the 300 Ω range is not included in error.
Resistance Test: Model 61-481 and 61-482
Range Source Reading
400Ω 360Ω
357.2 to 362.8
4KΩ 3.600KΩ
3.583 to 3.617
40KΩ 36.00KΩ
35.83 to 36.17
400KΩ 360.0KΩ
358.3 to 361.7
4MΩ 3.600MΩ
3.57 to 3.62
40MΩ 39.00MΩ
38.37 to 39.63
*Lead resistance on the 400 Ω range is not included in error.
*Press the Blue button to test
function
Continuity Beep Test: All Models
Range Source Test
20Ω
.Beeper on
50Ω
Beeper off
Buzzer will Alarm if resistance is less than approximately 30Ω
*Press the Blue button to test
function
Diode Test: All Models
Range Source Reading
500mV DC Approx. .485 - .515
Form number TM61480-1-2 Rev 5 July 2002