Page 3
SPECIFICATIONS (Model 61-480)
All specifications are warranted unless noted typical and apply to the 61-480.
Stated accuracies are at 23°C ±5°C at less than 80% relative humidity.
If Low Battery indicator is active then specification could be effective.
General specifications
Characteristics Description for 61-480
LCD display digits 3¾ LCD Display
Bargraph segments 70 Segment Graph
Display count 3200
Numeric update rate 2 times / sec
Polarity display Automatic
Over range display “OL” is displayed
Low voltage indicator “ ” is indicated
Automatic power-off time Automatic backlit off =1minutes
Power source 2 AAA dry cell battery
Maximum input voltage
1000V (750V AC) CAT II
Between V and COM
Maximum floating voltage
1000V (750V AC) CAT II between any
terminal and earth ground
Maximum input current
400mA between mA and COM, 10A
continuous between A and COM
Maximum open circuit
Voltage (current inputs)
600V between A and COM, and between
mA and COM
Overload protection mA connector 1A (500V) fast blow fuse
A connector 16A (500V) fast blow fuse
V connector
Ω
HZ
Temperature Coefficient
0.1 x (Spec. Accuracy) / °C < 18°C
or > 28°C .
Battery Life 500 hours typical (alkaline)
Form number TM61480-1-2 Rev 5 July 2002