INSTALLATION
Logic Combi ES - Installation and Servicing
FLUE OUTLET
14
DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED
IMPORTANT. The boiler must be installed in a vertical position in
accordance to the installation instructions.
FLUE KITS
 - contains: Flue turret, telescopic ue
incorporating a terminal and rubber wall seals.
 - contains:
Flue turret, non telescopic single piece ue incorporating a
terminal and rubber wall seals.
 - Flue turret,
telescopic ue incorporating a terminal, rubber wall seals and
instructions.
Note. If ‘B’ packs are used on their own (either 1 piece or telescopic), then
they can be tted horizontally as the ue inside is designed to slope 1.5
degrees.




When extension ‘D’ Packs are used the ue duct must incline
1.5 degrees away from the appliance, to allow the condensate
to drain back to the boiler and out of the condensate drain. It is
recommended that a support bracket is tted on every 1 metre of
pipe work used and the bracket is located as close to the collar as
possible. The bracketing must ensure a 1.5 degree fall back to the
appliance.
 - UIN 155988 & Concentric Flue
Screw Retaining Kit (Optional Kit of mechanical xing of ue
joints)
Only use water as a lubricant during assembly.
The ‘B’ pack terminal is classed as part of the maximum ue
length.
These ue systems incorporates a removable ue outlet
nose that utilises a push t location system. This enables the
installation of deector, high level or balcony ue kits without the
removal of the whole ‘B’ pack terminal. The appliance must not be
operated without the desired outlet nose correctly tted in place,
ensuring the side location dimples are in line with the mounting
face allowing the correct sealing of the components.
It is IMPORTANT that all attachments are tted in accordance to
the installation instructions provided with them.
The TURRET supplied in the ‘B’ Pack has an upper combustion
sample point with a screw cap seal and a lower air sample point
with an air stopper seal. Ensure all caps & seals are in place.
 available for use with these ‘B’
packs.
Flue Deector Kit The resistance is the equivalent of 1 metre of ue pipe and therefore must be deducted from
any maximum ue length
High Level Flue Outlet Kit
The maximum permissible concentric ue length when using a standard (500mm) kit is 4.5 metres
Balcony Flue Outlet Kit The maximum permissible concentric ue length when using this kit is dependant on the length
of the balcony ue outlet run which combined with the concentric run must not exceed the
maximum ue length requirement of the appliance it is to be tted to
Soft Kit This kit enables tment of an external ue below softs.
 combining both ‘B’ Packs and ‘D’ Packs
(Measured from centreline of the turret to the outside of the wall terminal)
24 kW appliances Total Maximum: 9 metres - minus any ue kit options or bends
30 kW Appliances Total Maximum: 8 metres - minus any ue kit options or bends
35 kW Appliances Total Maximum: 6 metres - minus any ue kit options or bends
combining both Roof Terminal and ‘D’ Packs
24, 30 & 35kW Appliances Total Maximum: 7.5 Metres - minus any bends

24, 30 & 35kW Appliances Total Maximum: 5 Metres - Concentric Flue and 17m ue pipe only. For additional details
refer to the powered Vertical Instructions
(Equivalent ue length resistance = 1M)
 - (Equivalent ue length resistance = 0.6M)
(Centre line of turret to outside of wall terminal)
Telescopic Flue ‘B’ Pack = 400mm
Horizontal Flue terminal (600mm long) ‘B’ Pack = 285mm
 Std Metric Brick 102.5mm wide
‘B’ Pack Flue Type 60/100  
Rear Flue   Rear Flue  
Horizontal Flue Terminal
(600mm long) B Pack
116 102.5 102.5 501 456 456
Telescopic Flue B Pack 231 186 186 429 384 384
Horizontal Flue Terminal
(1000mm long) B Pack
546 501 501 761 716 716
Horizontal Flue Terminal
(1000mm long) B Pack cut 75mm
471 426 426 686 641 641

