18: P
ULSE
O
UTPUT
I
NSTRUCTIONS
18-70 FC6A S
ERIES
MICROS
MART
L
ADDER
P
ROGRAMMING
M
ANUAL
FC9Y-B1726
2. S1 (source 1): Initial Value
Specifies the first data register of the devices that store the value for initialization or a constant.
Starting from the specified data register, 2 continuous words of data registers are used.
Specify the first data register so that the device range is not exceeded. The data type is L (long).
Storage Destination Setting
Starting number+0 Initial value (high word)
*1
-2147483648 to 2147483647
Starting number+1 Initial value (low word)
*1
*1 The upper and lower data registers change according to the 32-bit data storage method specified. For details, see "32-bit Data Storage" on
page 3-9.