25
UK
10.4 Service functions
10.4.1 Reset all parameters to factory setting
Select [rES]�
Briefly press [Enter]�
Keep [▲] or [▼] pressed.
> [----] is displayed�
Briefly press [Enter]�
> [ ] is displayed� The emissivity has to be reset (→ 10.2.1)
We recommend taking down your own settings in a table before carrying out
a reset (→ 15 Factory setting)
Menu EF:
[rES]
11 Operation
11.1 Changing the display unit in the Run mode
The temperature is displayed in the set standard unit of measurement (→ 10.3.1)
The display unit can be changed by pressing the pushbutton:
Briefly press [▼] or [▲] in the Run mode.
> The process value is displayed in the other temperature unit for 30 s; the
respective LED is lit�
11.2 Read the set parameters
Briefly press [Enter]�
Press [▼] or [▲] until the required parameter is displayed.
Briefly press [Enter]�
> The unit displays the currently set parameter value for 30 seconds� Then it
returns to the Run mode�
12 Technical data and scale drawing
Technical data and scale drawing at www�ifm�com�