CabinetModule CR2016
28
Index S-Idx Name Typ Default Beschreibung
F configuration
analogue input 3
rw u8 0x03 0x00 = off
0x03 = voltage 0���10,000 mV
0x06 = ratiometric 0���1000 per mille
0x07 = current 0���20,000 µA
0x09 = voltage 0���30,000 mV
0x0A = binary input
0x0B = binary input with diagnosis
10 configuration
analogue input 4
rw u8 0x03 0x00 = off
0x03 = voltage 0���10,000 mV
0x06 = ratiometric 0���1000 per mille
0x07 = current 0���20,000 µA
0x09 = voltage 0���30,000 mV
0x0A = binary input
0x0B = binary input with diagnosis
11 configuration binary
output 1
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 20���250 Hz)
0x0F = binary output with diagnosis
12 configuration binary
output 2
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 20���250 Hz)
0x0F = binary output with diagnosis
13 configuration binary
output 3
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 20���250 Hz)
0x0F = binary output with diagnosis
14 configuration binary
output 4
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 20���250 Hz)
0x0F = binary output with diagnosis
15 configuration binary
output 5
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 100 Hz)
0x0F = binary output with diagnosis
16 configuration binary
output 6
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 100 Hz)
0x0F = binary output with diagnosis
17 configuration binary
output 7
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 100 Hz)
0x0F = binary output with diagnosis
18 configuration binary
output 8
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 100 Hz)
0x0F = binary output with diagnosis
19 configuration binary
output 9
rw u8 0x02 0x00 = off
0x02 = binary output
0x04 = analogue output (PWM 100 Hz)
0x0F = binary output with diagnosis