en
12
User manual Gastroline www.igloo.pl
1 – Shelf fi xing handle
2 – Perforated frame strip
3 – Shelf in the container
Fig.4 Fixing the shelf in the container
2.3. Technical data
Table 1 Technical data
Name of the
device
Rated voltage
[V/Hz]
Rated current
[A]
Rated lighting
power [W]
Electric energy
consumption
[kWh/24h]
Utility volume
[dm3]
Weight of the
device [kg]
Gastroline 1.5 230/50 1,7 36 5,5 386 158
Gastroline 2.0 230/50 1,8 58 5,8 576 205
Gastroline 2.5 230/50 2,2 60 7,0 726 252
3. PREPARING THE DEVICE FOR EXPLOITATION
3.1. Requirements concerning the place of installation
• Verify whether the cross section of feeding conduits is proper for power consumption of the installed device.
• It is forbidden to connect the device by extension rods or dividers.
• The device should be connected to the separate, properly made electric circuit with plug-in socket with protecting pin
(according to PBUE /Regulations concerning Electric Equipment Construction/)
The device may be actuated solely after confi rmation of the fi re protection effi ciency with results
of measures performed according to binding regulations!
3.2. Connection and actuation
• Unpack the device
• The device should on an even and on a suffi ciently hard base, and then level it with the help of feet Fig.2/1 (p.11).
In case of moving devices it is necessary to use wheel blockade in order to immobilise them during exploitation Fig.2/2B (p.11) !
• If the user shall obtain a device partially disassembled to secure it during transportation, perform the following
operations:
1. Install shelf handle in perforated frame strips in the container of the display cabinet Fig.4/1 (p.12)
2. Place shelves on the fi xed handles Fig.4/3 (p.12)
3. Place GN container according to Fig.3 (p.11)
• The fi rst cleaning of the device should be provide right after unpacking, and before turning it on. The unit should
be cleaned with water at a temperature not exceeding 40°C with a neutral detergent. For washing and cleaning
the equipment it is prohibited to use products containing chlorine and sodium varieties, which destroy the protecti-
ve layer and components of the device! Any residue of adhesives or silicone on metal elements should be remo-
ved only with extraction naphtha (not applicable to items made of plastic !). Do not use other organic solvents.
When cleaning the unit is prohibited to use water jet. The unit should be cleaned with a wet rag.
After installation of the device at the destination place it should be left to rest for at least 2 hours before
turning it on (for devices with built in compressor) to set the level of refrigerant in order to prevent problems
with starting up the aggregate.
WARNING: Keep out the cooling circuit from damage!
3
12