Door seal should be cleaned solely with clean water without any cleansing agents and it should be
thoroughly dried. The seal cannot get into contact with oily substances or grease!
Control whether door close properly during maintenance procedures.
Test: place a sheet of paper between the seal and the casing and close the door. The paper
should pose a tangible resistance during an attempt to pull it out.
Elements of device can corrode when improper used and maintenance. To avoid that please
follow the rules:
• Do not allow contact of the surface of the device with substances containing chlorine and / or baking
soda in different varieties, which destroy the protective layer and components of the device (also
includes various stainless steel)
During maintenance services it is necessary to pay attention not to damage the data place of the device
Fig.9 (p.16), which contains signi cant information for servicing organs and waste removal companies.
6. SERVICE
6.1. Fault identi cation and repair
In case of any dif culties during actuation of the device or during its exploitation, please return to these chapters in this
manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still
experience dif culties, the following hints will help you solve the problem.
The device is not working... – Make sure that:
The device is connected to the supply network
Voltage and frequency in the network are compliant with those recommended by the producer, 230V/50Hz
The main switch is turned on
Thermostat is turned on (This concerns the Igloo thermostat – If only two spots are visible on the display – turn on
the thermostat)
The device is operating, but the lighting is off...– Make sure that:
Lighting switch is turned on
Fluorescent lamp or starting switch of the device are not burnt
Water leakage from below the device or into the inside of the chamber:
Check whether the device is properly levelled
Check the patency of out ow pipes
Check whether there is not too much ice in the pan and on the condenser – defrost when necessary
The device does not reach the proper temperature, the lighting is on...– Make sure that:
The main switch is on
Temperature setting on the thermostat is properly set
Thermostat works properly
The condenser is clean, if necessary – clean the condenser
Ambient temperature does not exceed 25ºC
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
Doors of the device close in a proper way and that the seal adjoins the frame of the device
Fig.8 Changing the uorescent lamp
1 – Fluorescent lamp handle
2 – Fluorescent lamp
3 – Casing of uorescent lamp and starting
switch
4 – Starting switch of uorescent lamp