TRADUCTION OF THE ORIGINAL INSTRUCTIONS FOR USE
BS 300/60 AFI-E ED.2010 rev.00
22/61
Use only if the working cycle time is shorter than 15 seconds.
If the machine is not working you can use the cleaning gun by pushing this button.
COOLANT OFF (22): by led light on, the coolant pump is always off, for example by dry cuttings or by setting
up the machine.
TEST (4) = Special functions for diagnostic
MODE (10) = Special functions for programming
The buttons on the right side (14 and 15) were used to memorize the cutting area on older versions of this
saw.
9.3.1 - INFORMATION ON DISPLAY /1 = functioning parameters
The key MODE (10) allows to display a series of data concerning the functioning of the machine. If you push
this button for an instant, a led light, corresponding to one of the five parameters of the machine, lights on
and you can read automatically on the display a value. If you push again MODE the following led lights,
corresponding to the other paramets, light on clockwise. The parameters are the following:
MACHINE CYCLE TIME = by led light (5) on. The display is in seconds "S" (more often), in minutes "n" or in
hours " ". Please note that the indicator adapts itself automatically to the passed time.
FUNCTIONING TIME OF THE MOTOR BLADE = by led light (6) on. Display as in MACHINE CYCLE
TIME”. The usual case is “ “ (on hours).
For band sawing machines this led light flashing indicates that there is a wrong or insufficient tension of
the band.
NUMBER OF CUT PIECES = by led light (7) on. Progressive display of numbers from 1 to 9999, and
following appearance of the points next to the numbers, that is from 1. to 9.9.9.9.
CUTTING SPEED PREVIOUSLY SET = by led light (8) on. In meters/minutes for bands (optional in
feet/minutes); in r.p.m. for circular blades and discs.
ELECTRICAL ABSORPTION = by led light (9) on. Maximum current load in Ampere pointed out in each
cutting cycle.
Each one of these parameters can be zero-set by pushing the keys TEST + MODE together for about
2 seconds, while the corresponding light is on.
The display (2) indicates constantly the electric motor absorption in Ampere, and by reading it together with
the display (3), you can get ERROR MESSAGES.
9.3.2. - INFORMATION ON DISPLAY / 2 = Errors table (SELF-DIAGNOSTICS)
The machine is equipped with self-diagnostics function, that allows to find out the working anomalies of the
machine and to inform the worker giving the code numbersindicated here below (the ones printed in bold type
are the most frequent):
DISPLAY ANOMALIES
ER0001 error in the configuration EEPROM
ER0002 error in the data checksum in EEPROM 1 1st. block
ER0003 error in the data checksum in EEPROM 2 2nd. block
ER0004 error in the data checksum in EEPROM 3 3rd. block
ER0005 error in the saved data in the permanent memory
ER0020 emergency active (emergency pushed?)
ER0021 motor overload protections (overheated motor?)
ER0022 open carter
ER0023 broken band
ER0024 FREE
ER0025 blocked inverter (motor under stress?)
ER0026 too high motor absorption
ER0027 not correct position of the tool for starting the cutting cycle (blade locked in the workpiece?)