3.19 COMBUSTION PARAMETERS.
G20 G30 G31
Gas nozzle diameter mm 1.35 0.78 0.78
supply pressure mbar (mm H
2
O) 20 (204) 29 (296) 37 (377)
Flue ow rate at nominal heat output kg/h 60 59 60
Flue ow rate at min heat output kg/h 64 67 66
CO
2
at Q. Nom./Min. % 7.10 / 2.05 8.40 / 2.30 8.15 / 2.30
CO at 0% of O
2
at Nom. Q./Min. ppm 70 / 155 109 / 180 71 / 183
NO
X
at 0% of O
2
at Nom.Q./Min. mg/kWh 157 / 102 269 / 125 220 / 125
Flue temperature at nominal output °C 109 113 111
Flue temperature at minimum output °C 77 79 76
- Fume temperature values refer to an air inlet
temperature of 15°C.
- e data relevant to domestic hot water per-
formance refer to a dynamic inlet pressure of
2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
3.20 TECHNICAL DATA.
Nominal heat input kW (kcal/h) 29.7 (25536)
DHW minimum heat input kW (kcal/h) 9.9 (8480)
CH minimum heat input kW (kcal/h) 12.7 (10902)
Nominal heat output (useful) kW (kcal/h) 28.0 (24080)
DHW minimum heat output (useful) kW (kcal/h) 8.5 (7310)
CH minimum heat output (useful) kW (kcal/h) 11.2 (9632)
Eciency at nominal heat output % 94.3
Eciency at 30% nominal heat output load % 91.5
Heat loss at case with burner On/O % 0.50 / 0.43
Heat loss at ue with burner On/O % 5.10 / 0.04
Central heating circuit max. operating pressure bar 3
Central heating circuit max. operating temperature °C 90
Adjustable central heating temperature °C 35 - 85
System expansion vessel total volume l 7.4
Expansion vessel factory-set pressure bar 1
Water content in generator l 2.8
Total head available with 1000 l/h ow rate kPa (m H
2
O) 32.46 (3.3)
Hot water production useful heat output kW (kcal/h) 28.0 (24080)
Domestic hot water adjustable temperature °C 30 - 60
Domestic hot water circuit ow limiter at 2 bar l/min 9.5
Min. pressure (dynamic) domestic hot water circuit bar 0.3
Domestic hot water circuit max. working pressure bar 10
Minimum D.H.W. ow rate l/min 1.5
Specic ow rate (∆T 30°C) l/min 13.4
Drawing capacity in continuous duty (∆T 30°C) l/min 13.6
Weight of full boiler kg 40.8
Weight of empty boiler kg 38.0
Electrical connection V/Hz 230/50
Power input A 0.74
Installed electric power W 130
Pump consumption W 84.0
Fan consumption W 41.0
Equipment electrical system protection - IPX5D
NO
X
class - 3
Weighted NO
X
mg/kWh 107
Weighted CO mg/kWh 92
Type of appliance C12 /C32 / C42 / C52 / C62 / C82 / B22p / B32
Category II2H3+
- The maximum sound level emitted during
boiler operation is < 55dBA. e sound level
value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with
extension of fume exhaust system according to
product standards.