3.25 TECHNICAL DATA.
- Flue temperature values refer to an air inlet
temperature of 15°C and ow temperature of
50°C.
- The maximum sound level emitted during
boiler operation is < 55dBA. e sound level
value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with
extension of ue gas exhaust system according
to product standards.
Victrix PRO 35 2ErP Victrix PRO 55 2ErP
Nominal heat input kW (kcal/h) 34.9 (30051) 51.3 (44098)
Minimum heat input kW (kcal/h) 3.9 (3388) 5.5 (4715)
Nominal heat output (useful) kW (kcal/h) 34.0 (29240) 49.9 (42914)
Minimum heat output (useful) kW (kcal/h) 3.4 (2924) 5.0 (4300)
Eciency 80/60 Nom./Min. % 97.3 / 86.3 97.3 / 91.2
Eciency 50/30 Nom./Min. % 107.0 / 94.7 106.8 / 99.7
Eciency 40/30 Nom./Min. % 107.3 / 100.2 107.4 / 103.5
Heat loss at casing with burner On/O (80-60°C) % 0.44 / 1.10 0.30 / 0.90
Heat loss at ue with burner On/O (80-60°C) % 0.04 / 1.60 0.03 / 1.80
Central heating circuit max. operating pressure bar 4.4 4.4
Central heating circuit max. operating temperature °C 90 90
Adjustable central heating temperature °C 20 - 85 20 - 85
Head available with 1000 l/h ow rate kPa (m H
2
O) 55.0 (5.61) 55.0 (5.61)
Weight of full boiler kg 54.0 54.2
Weight of empty boiler kg 51.2 51.4
Boiler water content l 2.8 2.8
Electrical connection V/Hz 230/50 230/50
Nominal absorption A 0.80 1.0
Installed electric output W 100 155
Pump consumption W 57 57
EEI - ≤ 0,23 - Part. 3 ≤ 0,23 - Part. 3
Fan power consumption W 28 79
Equipment electrical system protection - IPX5D IPX5D
Functioning room max. temperature °C +50 +50
Functioning room min. temperature °C -5 -5
Functioning room min. temperature with anti-freeze kit (Optional) °C -15 -15
Flue gas max. temperature °C 75 75
NO
X
class - 5 5
Weighted NO
X
mg/kWh 25 39
Weighted CO mg/kWh 8 15
Type of appliance C13 / C33 / C63 / B23p / B33 / B53p
Category II2H3P