3.27 TECHNICAL PARAMETERS FOR MIXED BOILERS IN COMPLIANCE WITH REGULATION 813/2013.
e yields in the following tables refer to the higher heating value.
Model/s: Victrix Pro 35 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
34 kW
Seasonal energy eciency of central
heating
η
s
91 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
34.0 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
86.8 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
10.2 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
95.6 %
Auxiliary electricity consumption Other items
At full load el
max
0.043 kW Heat loss in standby P
stby
0.091 kW
At partial load el
min
0.015 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.006 kW Emissions of nitrogen oxides NO
X
23
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Model/s: Victrix Pro 55 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
50 kW
Seasonal energy eciency of central
heating
η
s
91 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
49.9 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.7 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
15.0 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
95.8 %
Auxiliary electricity consumption Other items
At full load el
max
0.091 kW Heat loss in standby P
stby
0.091 kW
At partial load el
min
0.015 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.006 kW Emissions of nitrogen oxides NO
X
36
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.