3.27 TECHNICAL PARAMETERS FOR MIXED BOILERS IN COMPLIANCE WITH REGULATION 813/2013.
e yields in the following tables refer to the higher heating value.
Model/s: Victrix Pro 35 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
34 kW
Seasonal energy eciency of central
heating
η
s
91 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
34.0 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
86.8 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
10.2 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
95.6 %
Auxiliary electricity consumption Other items
At full load el
max
0.043 kW Heat loss in standby P
stby
0.091 kW
At partial load el
min
0.015 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.006 kW Emissions of nitrogen oxides NO
X
23
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Model/s: Victrix Pro 55 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
50 kW
Seasonal energy eciency of central
heating
η
s
91 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
49.9 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.7 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
15.0 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
95.8 %
Auxiliary electricity consumption Other items
At full load el
max
0.091 kW Heat loss in standby P
stby
0.091 kW
At partial load el
min
0.015 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.006 kW Emissions of nitrogen oxides NO
X
36
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas VICTRIX PRO 35 2ErP and is the answer not in the manual?

Immergas VICTRIX PRO 35 2ErP Specifications

General IconGeneral
BrandImmergas
ModelVICTRIX PRO 35 2ErP
CategoryBoiler
LanguageEnglish

Related product manuals