85
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
3.23 REPLACING THE MANIFOLD INSULATING PANEL
e operations described below must be performed aer having removed the voltage from the
appliance.
Victrix Tera V2 28 EU - V2 32 EU
1. To access the inside of the appliance, remove the casing as indicated in Paragr. 3.22.
2. Unscrew the 4 manifold fastening nuts (1, Fig. 66) and gently pull them out orthogonally towards yourself.
3. Remove the insulating panel (1) by actuating a blade (2) under its surface.
4. Unscrew the xing screws (6) of the ignition and detection electrode (5) and remove it.
5. Remove the residue of the xing adhesive from the surface of the manifold (3).
6. Replace the insulating panel (1).
e new insulating panel, used as a spare to replace the removed one, does not need to be xed with glue as its shape with the in-
terference on the burner ensures correct coupling with the manifold.
7. Ret the ignition and detection electrode (5) using the previously removed screws (6) and replace the relative gasket (4).
1
3
4
5
6
2
1
60
Electrode distance
To regain optimal operation, make sure that the following variables are respected when retting the electrodes.
3,5±-0,5
7±1