2 Specifications
Inverter type VXS… 20-1 40-1 75-1 150-1 220-1 40-3 75-3 150-3 220-3 400-3
2.1 Output Ratings Single-phase Input Three-phase Input
Nominal applied motor kW 0.2
0.4/
0.75 1.5 2.2
0.4/
0.75 1.5 2.2 4.0
0.55 0.55
Rated capacity* kVA 0.6 1.2 2.0 3.2 4.4 1.2 1.8 2.7 4.0 6.5
Voltage V 0V to V
L
Frequency Hz 0.2Hz to 400Hz
Rated
Low PWM freq. A 1.5 3.0 5.0 8.0 11.0 1.6 2.5 3.7 5.5 9.0
current
High PWM freq. A 1.3 2.5 4.0 7.0 10.0 1.4 2.1 3.7 5.3 8.7
Overload capability
150% of rated current for 1 minute
200% of rated current for 0.5s
2.2 Input Ratings Single-phase Input Three-phase Input
Rated current (rms) A 2.95 4.1 7.2 14 20 1.3 2.2 4.3 6.0 9.8
Min. supply capacity kVA 0.7 1.2 1.8 3.2 4.5 0.7 1.2 2.2 3.1 5.0
MCB rating with DC reactor A6 6 101020 6 6 6 1010
without DC reactor A 6 10 16 20 32 6 6 10 16 16
Fuse rating with DC reactor A1010203240 6 6 101020
without DC reactor A1010203240 6 6 101020
Phase; Voltage V
L
; Frequency 1-ph; 200/240V; 50/60Hz 3-ph; 380/415V; 50/60Hz
Voltage +10% to -10% +10% to -15%
Variations Imbalance — Max. 3% of line to line voltage
Frequency +5% to -5%
2.3 Output Frequency Single-phase Input Three-phase Input
Max. frequency Hz 0.2Hz to 400Hz
Base freq. setting range Hz 15Hz to 400Hz
Starting freq. setting range Hz 0.2Hz, 1Hz to 60Hz (minimum unit 1Hz)
Carrier freq. setting range kHz 0.75kHz, 1kHz to 15.6kHz (minimum unit 1kHz)
Accuracy (stability)
Analog ±0.2% of Maximum O/P Frequency (25
o
C ±10
o
C)
Digital ±0.01% of Maximum O/P Frequency (-10
o
C to +50
o
C)
Analog
1/3000 of Max. O/P Frequency
eg 0.2Hz if max. is 60Hz; 0.4Hz if max. is 120Hz, etc
Setting resolution
Digital
0.01Hz up to 99.99Hz output frequency and
0.1Hz from 100Hz output frequency upwards
2.4 Braking Single-phase Input Three-phase Input
Braking torque
without resistor ≥100% ≥70% ≥40% ≥100% ≥50%
with resistor — ≥150% ≥100% ≥150% ≥100%
Starting frequency: 0.2Hz to 60Hz
DC Injection Braking Braking time: 0.01s to 30s
Braking level: 0 to 100% of rated current
2.5 General Single-phase Input Three-phase Input
Heat loss Please refer to data on page 64
Enclosure IP40, all models (side covers in place)
Cooling method Convection Fan-assisted Convection Fan-assisted
Mass kg 1.1 1.6 1.7 2.7 2.8 1.8 1.8 2.7 2.7 3.2
* At 230V single phase or 415V three phase.
3