Chapter8 Communication Function
8-46
(Continued)
Error code Error type Error condition and causes Treatment
H6001 Syntax error
* When use commands that aren t supported.
Ex1) When use device
like %MX100 in RSB command
* Be familiar with the manual.
* Check if the system stopped.
* reset
H6010 Syntax error * OVER-RUN, FRAME error * Be familiar with the manual.
H6020 Syntax error * TIME_OUT error
* Confirm the setting of the communication
ports of RS-232C.
* reset
H6030 Syntax error * Syntax error in commands * Check if each sends frame has ENQ, EOT.
H6040 Syntax error When a FRAME text exceeds over 256 bytes.
* Rearrange send frame not to go over 256
bytes.
H6050 Syntax error * BCC error * Check if BCC is right.