ACF5 0601.01 GB
www.imo.se
5
1
m
Before commencing any work, read this instrucion carefully! Failure to comply with these instrutions
may cause damage and personal injury!
For more information about the pumps identication code, technical data and performance we refer to the ACF
Product description.
Pump size
Pos 080 090 100 110 125
G011 Rotor set N-lead 192966 192968 192970 192972 192974
CCW K-lead 192967 192969 192971
L-lead 192973 192975
G012 Rotor set N-lead 192785 192958 192960 192962 192964
CW CW K-lead 192786 192959 192961
L-lead 192963 192965
G050 Sha seal xVxx 192525 192525 192526 192526 192526
G053 Minor kit xVxx 192987 192987 192988 192988 192989
G057 Joint kit xVxx 192990 192990 192991 192991 192992
G070 Valve xxxP 192553 192553 192554 192554 192555
G099 Complete IEC 132 192993 192997
sha IEC 160 192994 192998 193002 193002 193002
coupling IEC 180 192995 192995 193003 193003 193003
IEC 200 192996 192996 193004 193004 193004
IEC 225 193001 193005 193005 193005
IEC 250 193006 193006 193006
IEC 280 193007 193007 193007
Kit Contents To be used for
G057 Gaskets, o-rings,
ball bearing, etc
Dismantling of
the pump
G053 G057 + Sha seal
G050
Normal sched-
uled inspection
G054 G053 + Complete
rotor set
Repair aer major
breakdown or
great wear
Recommended Spare Parts Kits
Every shutdown for service of a plant is
costly. The time for repair should therefore
be limited to a minimum which can be
accomplished by keeping a spare pump.
The changed pump can later be repaired at
a suitable place and can then be used as a
spare pump. For maintenance the following
spare parts kits are recommended:
Ordering Code