EasyManua.ls Logo

IMO Jaguar CUB - Page 101

IMO Jaguar CUB
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-29
The following tables list the discharging capability and allowable average loss of the Jaguar CUB
series inverters. These values are determined by inverter model and specifications of braking
resistors.
External braking resistor
Continuous braking
(Braking torque:
100%)
Repetitive braking
(Period: 100 sec. or
less)
Power
supply
voltage
Inverter type
Braking
resistor
type
Q'ty
Resis-
tance
(
:
)
Cap
acity
(W)
Discharg-
ing
capability
(kWs)
Braking
time
(s)
Allowable
average loss
(kW)
Duty
cycle
(%ED)
CUB3A-2 250 37
CUB5A-2
See IMO 100 200 50
133
0.075
20
CUB8A-2 73 14
CUB11A-2
See IMO 40 400 55
50
0.110
10
Three-
phase
200V
CUB17A-2 See IMO 33 400 140 75 0.185 10
CUB1A5-4 250 37
CUB2A5-4
See IMO 200 200 50
133
0.075
20
CUB3A7-4 73 14
CUB5A-4
See IMO 160 55
50
0.110
10
Three-
phase
400V
CUB9A-4 See IMO 130
400
140 75 0.185 10
CUB3A-1 250 37
CUB5A-1
See IMO 100 200 50
133
0.075
20
CUB8A-1 73 14
Single-
phase
200V
CUB11A-1
See IMO
1
40 400 55
50
0.110
10

Table of Contents

Related product manuals