7.2 Evaporator
Some COMPACT CLASSIC models have "O" shaped corner evaporators, other models
instead have at evaporators. Flat evaporators can be folded/bent to adapt to go
into a compartment. Specic areas in which these can be bent exist for this purpose.
See the nal part of this paragraph to nd out which are the bending zones for each
model and how to proceed.
Evaporator installaon does not require bending.
The instrucons below should be followed when installing an evaporator not
requiring bending inside a compartment to convert it into a fridge or freezer:
1. Carefully plan the evaporator posion: the locaon on the side of the
compartment where you can install the internal unit and make a hole in which to
pass quick couplings.
2. The evaporator must be installed so that it covers as wide an area as possible of
the vercal wall. For freezer version installaon, posion so as to reach 2 or more
sides where possible. The evaporator must be installed as high as possible inside
the compartment to be cooled to opmise yield and temperature distribuon
inside the compartment.
3. It is very important that the short part of the hose aached to the evaporator via
a jumper remain directed towards the wall.
Be sure to leave enough space for this hose because it should not be removed in
any case from its mounng to alter the length.
4. Both the sucon hose and the small capillary hose should be rolled up carefully
before installing the evaporator, keeping the protecve covers on connecons as
long as the connecon is not going to be made. Starng from the inside of the
compartment to be cooled, lay the hose with its two connecons through the
hole made previously on the bulkhead unl reaching the compressor, making
sure not to choke or crush the hose. The excess part of the hose must be carefully
wound in a spiral (Ø = 30 cm) before being fastened to thus prevent resulng
vibraon or noise. These acons must be completed before removing quick
coupling protecons.
5. Mark the posion of the mounng holes using the screws and spacers provided.
Do not use screws that are longer than necessary as they could completely pierce
wall insulaon.
6. Install the evaporator screwing the screws and spacers into the previously made
holes.