7.6 Start-up
Test the operaon of the unit by turning the thermostat knob in a clockwise
direcon. The compressor must start up within 30 seconds, aer which you will hear
a slight hum. The fan will also start up a few minutes aer the evaporator starts to
freeze. You can adjust the temperature considering that the lowest temperature can
be obtained by rotang the knob clockwise and the highest temperature, conversely,
by bringing the knob to the posion closest to that of the circuit breaker. To stop
unit operaon, fully rotate the same knob in a counter clockwise direcon. The
thermostat opposes some resistance which must be countered.
7.7 Electrical mains power supply
Connecon to the electrical mains can be made for Compact Classic operaon.
When using a baery charger, always connect it to the baery and never to the
refrigerator's electronic unit. An even beer soluon is installing a "Power Pack"
transformer, an oponal accessory, which switches automacally from baery power
to electrical power when the laer is connected.
When using a AC/DC (115/230 Vac and 12-24 Vdc) control unit, make sure that:
- the connecon is double insulated as in the gure
Figure 11: Detail of double insulated connecon
- the earthing cable is longer than the other cables to ensure it will the last to
disconnect if pulled.
- the earthing cable is connected via a screw on the metal structure/s of the
compressor as indicated in the gure in the suitable allocaon
User Manual