7.6 Start-up
Test the operaon of the unit by turning the thermostat knob in a clockwise
direcon. The compressor must start up within 30 seconds, aer which you will hear
a slight hum. The fan will also start up a few minutes aer the evaporator starts to
freeze. You can adjust the temperature considering that the lowest temperature can
be obtained by rotang the knob clockwise and the highest temperature, conversely,
by bringing the knob to the posion closest to that of the circuit breaker. To stop
unit operaon, fully rotate the same knob in a counter clockwise direcon. The
thermostat opposes some resistance which must be countered.
7.7 Electrical mains power supply
Connecon to the electrical mains can be made for Compact Classic operaon.
When using a baery charger, always connect it to the baery and never to the
refrigerator's electronic unit. An even beer soluon is installing a "Power Pack"
transformer, an oponal accessory, which switches automacally from baery power
to electrical power when the laer is connected.
When using a AC/DC (115/230 Vac and 12-24 Vdc) control unit, make sure that:
- the connecon is double insulated as in the gure
Figure 11: Detail of double insulated connecon
- the earthing cable is longer than the other cables to ensure it will the last to
disconnect if pulled.
- the earthing cable is connected via a screw on the metal structure/s of the
compressor as indicated in the gure in the suitable allocaon
User Manual