Maintenance Summary - Care activities
It is recommended to document the maintenance activities carried out by using the appropriate
maintenance log. The maintenance log has the document number DIE249EN - 15.08.2022.
The maintenance interval is highly dependent on the production and environmental conditions of the
machine. The determination of the appropriate interval must be made by the operator.
The maintenance interval should be between once per shift and once a week!
A010 - Check the work area door and window pane
A024 - Check hydraulic system (visual inspection)
A027 - Replace the breathing filter at the filler neck of the hydraulic fluid tank.
A042 - Check pneumatic system (visual inspection)
A049 - Check the lubrication system (visual inspection)
A065 - Lubricate turret steady rest SR2 or SLU X1 (by SMW)
A075 - Check fill levels of the fluid tanks
A080 - Clean and lubricate clamping device
A090 - Check electrical lines (visual inspection)
A095 - Visual inspection of all fluid lines and electrical cables
A103 - Clean cooling lubricant outlet on clamping cylinder
A120 - Check cooling lubricant (visual inspection)
A126 - Check the cooling unit and the coolant
A132 - Check work area light (visual inspection)
A140 - Check HSK clamping set and, if necessary, lubricate (Ott-Jakob)
A145 - Maintenance of HSK clamping sets (from Berg)
A180 - Clean the work area
A215 - Check slat/shingle cover on the telescopes (visual inspection)
A255 - Clean the chip conveyor
A320 - Wassermann tool change system