INSTINCT User Manual rev 01 04/18 41
Section 5 Troubleshooting
Troubleshooting — Error Code
Error Code
( Display)
Problem Action
Normal Operation. Normal Operation.
E01 Unsuitable induction cooking pan.
Internal wiring/coil connection
malfunction. (2)
Check pan material.
Contact an authorized service agency.
E02 Unsuitable induction cooking pan.
Coil overcurrent. (2)
Check pan material.
Contact an authorized service agency.
E03 + Air-cooling system obstructed. Fan
malfunction.
Heat sink overheated. (2)
Let appliance cool down.
Verify that air vents are not obstructed.
Check and clean air filter.
Contact an authorized service agency.
E04 + Overheated cook zone. Overheated pan
detected. Sensor failure.
Let appliance and/or pan cool down.
Check pan material.
Verify that air vents are not obstructed.
Check and clean air filter.
Contact an authorized service agency.
E41, E42,
E43, E44,
E45, E46
Overheated or defective sensor. (2)
NOTE: Errors E41 to E46, griddles and
braising pans may continue to operate.
E06, E30 + Ambient temperature too high (the
cooling system is not able to keep the
induction appliance in normal operating
conditions). Internal component
overheated. (2)
Let appliance cool down.
Verify that air vents are not obstructed.
Check and clean air filter.
Verified that no hot air is taken in by the fan. Reduce the ambient
temperature. The intake air temperature must be lower than 40°C [104°F].
Contact an authorized service agency.
E29 Generator component failure. (2) Contact an authorized service agency.
E47 Warning from overheated pan / cooking
empty sensor or coil connection failed. (2)
Let equipment / pan cool down.
Check pan material.
Check food in the pan or empty pan.
E21 + Sensor error from heat sink. Ambient
temperature beyond normal operating
range. (2)
Verify that air vents are not obstructed. Check air filter. Reduce ambient
temperature.
Contact an authorized service agency.
E24 + Sensor error from CPU. Board overheated.
Ambient temperature beyond normal
operating range. (2)
Verify that air vents are not obstructed. Check air filter. Reduce ambient
temperature.
Contact an authorized service agency.