3.4.2 Install IAR Embedded Workbench and SDL
Install IAR Embedded Workbench in advance and ensure that the licenses are properly enabled.
Install SDL according to SDL's instructions.
3.4.3 Set up debug script and configuration files
Replace I-jet DLL to support SWD_v2.
1. Locate IAR SWD DLL. It is available at the location: /misc/iar/SigJtag_1_87.zip.
2. Unzip the SigJtag_1_87.zip for SigJtag.dll.
3. Replace the old DLL with the new one:
(Typical path: aC:\Program Files (x86)\IAR Systems\Embedded Workbench 8.4\arm\bin\jet\bin)
Replace old DLL
SDL folder IAR Systems folder
Figure 7 Replace DLL
Copy flash loaders to support PSoC
™
HV PA
1. Locate flash loaders. They are available at the location: /misc/iar/IAR_EWARM_8421_Patch_PSoC4HV.7z
2. Extract IAR_EWARM_8421_Patch_PSoC4HV.7z.
3. Copy the extracted package ("arm" folder) to the IAR installation folder.
(example, C:\Program Files (x86)\IAR Systems\Embedded Workbench 8.4\arm)
a. src: IAR_EWARM_8421_Patch_PSoC4HV\arm\config\debugger\Infineon to
dst: \config\debugger\Infineon
b. src: IAR_EWARM_8421_Patch_PSoCHV\arm\config\devices\Infineon\PSoC4\PSoC4-HV-PA to
dst: \config\devices\Infineon\PSoC4
c. src: IAR_EWARM_8421_Patch_PSoC4HV\arm\config\flashloader\Infineon to
dst: \config\flashloader\Infineon
Getting started with PSoC
™
HV PA family
3 Development environment and tools
Application note 19 002-30264 Rev. *B
2023-04-19