135
Environment
Humidity
5 to 95% (non condensing operating and non-operating)
Temperature
Operating:
a. With Battery Backup Module 0º to 35ºC
b. Without Battery Backup Module 0º to 40ºC
Non-operating: -40º to 60ºC
Altitude
Operating: Sea level to 12,000ft
Packaged: Sea level to 40,000ft
Shock (Half-sine)
Operating: 5G, half-sine, 11ms pulse width
Non-operating: 15G, half-sine, 11ms pulse width
Vibration
(Random)
Operating: 5 to 500Hz, 0.25Grms, X/Y/Z, 30min
Non-operating: 5 to 500Hz, 1.0Grms, X/Y/Z, 30min
(Sine)
Operating: 5 to 500Hz, 0.2Grms, X/Y/Z Sine, 1hr/sweep
Non-operating: 5 to 500Hz, 1.0Grms, X/Y/Z Sine, 1hr/sweep
Acoustic Noise
65dBA boundary, 60dBA normal

Table of Contents