IDS404 INSTALLER MANUAL NO. 700-277-02A ISSUED SEPT 2004 VER 1.02 41
IDS404 INSTALLER MANUAL
721-621SNOITACOLedocgnitroperrepmaTneriS
The siren tamper condition will be reported if the siren wire is open
circuit or the fuse has blown.
821NOITACOLedocgnitroperyawA&esolC
The close code will be reported when the system is armed in the
AWAY mode indicated by illuminated ARMED and AWAY LED’s on
the keypad.
NOTE:
The close code will not be reported if the system is armed in the STAY
mode. The digit programmed into this location is the first digit of the
reporting code. The second digit will automatically be added and will
be the number which corresponds to the user code used to arm the
system (See Users Manual).
EXAMPLE:
If a close code of C (12) is programmed and the master user code is
used to arm the system the 2 digit reporting code would be C1
indicating a close by user 1.
NOTE:
If the system is armed using the quick arm “AWAY” key the system
will report a close by user 1.
If the system is armed by means of a key or remote using an arm/
disarm zone the system will report a close by user 13.
921NOITACOLedocgnitropernepO
The open code will be reported when the system is disarmed.
NOTE:
The open code will not be reported if the system was armed in the
stay mode and the stay arming reporting code (location 130) is 0 i.e.
Disabled.
The digit programmed into this location is the first digit of the reporting
code. The second digit will automatically be added and will be the
number which corresponds to the user code used to disarm the
system (See Users Manual).
EXAMPLE:
If an open code of B (11) is programmed and the master user code is
used to disarm the system, the 2 digit reporting code would be B1