Do you have a question about the Innotech Micro2000 M2K04 and is the answer not in the manual?
Details of voltage and power consumption requirements for the controller.
Specifies the types of inputs supported, including thermistor and digital inputs.
Lists the voltage-free relay contacts for various output functions.
Explains the 4-way connection method between the controller and control station.
Identifies terminals on control station and controller for power, communication, and signals.
Information on the type, voltage, and disposal of the controller's lithium battery.
Specifies storage, operating, and sensor input temperature ranges.
Describes the primary use of Micro2000 Series Controllers in commercial HVAC systems.
Highlights key functionalities like pump interlock, LED display, and programmable schedules.
Lists the electromagnetic emission and immunity standards the controller conforms to.
Provides guidelines for mounting, wiring, and connecting the Micro2000 controller.
Explains common fault messages like 'HELP', 'SEN FAIL', and 'no FLO'.
Details the 3-wire pump interlock system and its interaction with the M2KPI module.
Details Input 1 (temperature sensor) and Input 2 (selectable digital input functions).
Explains specific operational states like AC Fault, External Disable, and Door Switch modes.
Maps controller relays to specific functions like Fans, Heat 1, Heat 2, Cool 2, and Cool 1.
Describes the function of the Auto and A/H buttons for schedule control and after hours operation.
Instructions for viewing and resetting the accumulated After Hours Run Time.
How to set and save the controller's default operating modes.
Guidance on setting up daily on/off schedules and overriding them with holiday schedules.
Process for entering programming mode, selecting, and adjusting parameters from 00 to 17.
Key information on saving alterations, timeouts, and reverting to last saved settings.
Covers sensor calibration, setpoints, dead band, proportional band, after hours, and compressor timing.
Details operating modes (EDH/REV), heating/cooling control, fan cycles, display options, and input functions.
Advises against touching terminals with power, disassembling the unit, and stresses the need for external safety measures.
Illustrates the wiring for the Electric Heat connection, including controller and supply connections.
Illustrates the wiring for the Reverse Cycle connection, including compressor and reversing valve.
The Innotech Micro2000 Series Controllers (M2K04) are designed for commercial air conditioning systems, particularly those requiring a condenser water pump interlock system. These controllers provide comprehensive control over various aspects of an HVAC system, including fan, cooling, and heating operations, with advanced scheduling and monitoring capabilities.
The M2K04 controller is a 1-speed FAN, 2 COOL, and 2 HEAT controller, featuring a 365-day battery-backed real-time clock. It integrates a condenser water pump interlock system, ensuring proper pump operation in conjunction with the compressor. The controller manages temperature based on a 10kΩ thermistor input and allows for digital input from switched contacts. It can operate in either 2 cool, 2 electric heating, or reverse cycle heating/cooling modes. The device supports programmable schedules with four events per day and programmable holidays (20 On/Off dates). An "After Hours" function is included, with the ability to store accumulated After Hours Run Time.
Power Supply:
Inputs:
Outputs (Voltage-free relay contacts):
Battery:
Temperature Ratings:
Physical Dimensions:
Approvals:
Control Station: The control station features an LED display for temperature and program functions, fitting standard electrical wall plates. It connects to the controller via a 4-way, 3-core plus screen cable, simplifying installation.
Push Buttons:
Programming Modes:
Fault Representation:
Condenser Water Pump Interlock Control: The M2K04 is equipped with a 3-wire pump interlock system. When Compressor One is called, the controller sends a "Call" signal to the Pump Interlock Module. The module enables the pump and sends a "Verify" signal when flow is achieved, allowing the controller to enable Compressor One. When Compressor One turns off, the "Call" signal remains on for the time set in Parameter 17 (CW Run On Time) to allow the pump to run on. Multiple M2K04 controllers can be connected in parallel to a single Pump Interlock Module.
Battery Replacement: The device contains a CR-2032 lithium battery. Users are cautioned about the risk of explosion if the battery is replaced with an incorrect type. Proper disposal in accordance with local regulations is required.
Installation Guidelines:
Safety Precautions:
Programming Notes:
| Brand | Innotech |
|---|---|
| Model | Micro2000 M2K04 |
| Category | Controller |
| Language | English |