4
CAUTION
Prevent dropping metal 󶍾lings and wire ends drop into ventilation holes of the PLC at wiring.
Failure to comply may result in 󶍾re, fault and malfunction.
The external wiring speci󶍾cation and installation method must comply with local regulations.
For details, see the wiring section in this guide.
To ensure safety of equipment and operator, use cables with su󶎀cient diameter and connect
the cables to ground reliably.
Ensure that all cables are connected to the correct interface. Failure to comply may result in
module and external equipment fault.
Tighten bolts on the terminal block in the speci󶍾ed torque range. If the terminal is not tight,
short-circuit, 󶍾re or malfunction may be caused. If the terminal is too tight, fall-o󶍽, short-circuit,
󶍾re or malfunction may be caused.
If the connector is used to connect with external equipment, perform correct crimping or
welding with the tool speci󶍾ed by manufacturer. If connection is in poor contact, short-circuit,
󶍾re or malfunction may be caused.
A label on the top of the module is to prevent foreign matters entering the module. Do not
remove the label during wiring. Remove it before operation for ventilation.
Do not bundle control wires, communication wires and power cables together. They must be
run with distance of more than 100 mm. Otherwise, noise may result in malfunction.
Select shielded cable for high-frequency signal input/output in applications with serious
interference so as to enhance system anti-interference ability.
Operation and Maintenance
WARNING
Maintenance & inspection must be carried out by quali󶍾ed personnel.
Do not touch the terminals while the power is on. Failure to comply may result in electric shock or malfunction.
Disconnect all external power supplies of the system before cleaning the module or re-
tightening screws on the terminal block or screws of the connector. Failure to comply may
result in electric shock.
Disconnect all external power supplies of the system before removing the module or connecting/
removing communication wirings. Failure to comply may result in electric shock or malfunction.
CAUTION
Get with the guide and ensure safety before online modi󶍾cation, forcible output, and RUN/
STOP operation.
Disconnect the power supply before installing/removing the extension card.
Disposal
CAUTION
Dispose of the product as industrial waste.