5 Parameter Table
- 30 -
Para. No. Para. Name Setting Range Default Comms. Address
F2-09
Torque limit source in speed
control
0: F2-10
1: AI
2: External operating panel
4: Pulse reference (DI5)
5: Serial communication
6: Minimum (AI1, AI2)
7: Maximum (AI1, AI2)
0 0xF209/0x0209
F2-10
Digital setting of torque limit in
speed control
0.0% to 200.0% 150.0% 0xF20A/0x020A
F2-11
Torque limit source in speed
control (in regenerative state)
0: F2-10
1: AI
2: External operating panel
4: Pulse reference (DI5)
5: Serial communication
6: Minimum (AI1, AI2)
7: Maximum (AI1, AI2)
8: F2-12
0 0xF20B/0x020B
F2-12
Digital setting of torque limit in
speed control (in regenerative
state)
0.0% to 200.0% 150.0% 0xF20B/0x020B
F2-13
Excitation adjustment proportional
gain
0 to 60000 10 0xF20D/0x020D
F2-14
Excitation adjustment integral
gain
0 to 60000 10 0xF20E/0x020E
F2-15
Torque adjustment proportional
gain
0 to 60000 10 0xF20F/0x020F
F2-16 Torque adjustment integral gain 0 to 60000 10 0xF210/0x0210
F2-17 Speed loop property
Torque feed-forward
0: Disabled
1: Enabled
Integral separation
0: Disabled
1: Enabled
00 0xF211/0x0211
F2-18 Torque feed-forward gain 20 to 100 80 0xF212/0x0212
F2-19 Torque feed-forward lter time 10 to 200 50 0xF213/0x0213
F2-21
Max. torque coefcient of eld
weakening area
50% to 200% 80% 0xF215/0x0215
F2-22 Regenerative power limit
0.0%: no limit
0.1% to 200.0%
0.0% 0xF216/0x0216
Group F3: V/F Control Parameters
F3-00 V/F curve setting
0: Linear V/F
1: Multi-point V/F
10: V/F complete separation
11: V/F half separation
0 0xF300/0x0300