5 Parameter Table
- 38 -
Para. No. Para. Name Setting Range Default Comms. Address
F7-05 LED display stop parameters
0000 to 1FFF
7 6 5 4 3 2 1 0
Bus voltage (V
)
DO state
AI voltage (V)
Count value
Frequency reference
(Hz)
DI state
Reserved
External operating panel
potentiometer voltage (V)
15 14 12 11 10 9 8
PLC stage
Pulse reference (kHz)
Length value
Reserved
13
Load speed
PID reference
Reserved
Reserved
0033 0xF705/0x0705
F7-06 Load speed display coefcient 0.0001 to 65.000 1.0000 0xF706/0x0706
F7-07 IGBT heatsink temperature 0°C to 100°C - 0xF707/0x0707
F7-08 Product series 200 - 0xF708/0x0708
F7-09 Accumulative running time 0 to 65535h - 0xF709/0x0709
F7-10 Performance software version - - 0xF70A/0x070A
F7-11 Function software version - - 0xF70B/0x070B
F7-12
Number of decimal places for
load speed display
10 to 23
1: 1 decimal place
2: 2 decimal places
Number of decimal places
of U0-14
0: 0 decimal place
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
Number of decimal
places of U0-19/U0-29
21 0xF70C/0x070C
F7-13 Accumulative power-on time 0 to 65535 h - 0xF70D/0x070D
F7-14 Accumulative power consumption 0 to 65535 kWh - 0xF70E/0x070E
Group F8: Auxiliary Functions
F8-00 Jog frequency reference 0.00 Hz to maximum frequency 2.00 Hz 0xF800/0x0800
F8-01 Jog acceleration time 0.0 to 6500.0s 20.0s 0xF801/0x0801
F8-02 Jog deceleration time 0.0 to 6500.0s 20.0s 0xF802/0x0802
F8-03 Acceleration time 2 0.0 to 6500.0s 20.0s 0xF803/0x0803
F8-04 Deceleration time 2 0.0 to 6500.0s 20.0s 0xF804/0x0804
F8-07 Acceleration time 4 0.0 to 6500.0s 0.0s 0xF807/0x0807
F8-08 Deceleration time 4 0.0 to 6500.0s 0.0s 0xF808/0x0808
F8-12
Forward/Reverse run switchover
dead-zone time
0.0 to 3000.0s 0.0s 0xF80C/0x080C