EasyManua.ls Logo

Inovance MD210 Series - Page 25

Inovance MD210 Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 23 of 43
Display
Fault Name
Possible Causes
Solutions
Err08
Undervoltage
for times
1: Instantaneous power off.
2: The DC bus voltage is too low
ƿ
.
3: The rectifier bridge and buffer resistor are faulty.
4: The drive board is faulty.
5: The control board is faulty.
Check the power supply, or seek for maintenance.
Err09
Undervoltage
1: Instantaneous power off.
2: The DC bus voltage is too low
ƿ
.
3: The rectifier bridge and buffer resistor are faulty.
4: The drive board is faulty.
5: The control board is faulty.
1: Reset.
2: Check the DC bus.
3 to 6: Seek for maintenance.
Err10
Drive overload
1: The load is too heavy or the rotor is locked.
2: The drive is of too small power class.
1: Reduce the load, or check the motor, or check the
machine whether it is locking the rotor.
2: Select a drive of higher power class.
Err11
Motor overload
1: F9-01 is too small.
2: The load is too heavy or the rotor is locked.
3: The drive is of too small power class.
1: Set F9-01 correctly.
2: Reduce the load, or check the motor
, or check the
machine whether it is locking the rotor.
3: Select a drive of larger power class.
Err12
Power input
phase loss
1: The three-phase power supply is abnormal.
2: The drive board is faulty.
3: The lightening protection board is faulty.
4: The control board is faulty.
1: Check the power supply.
2 to 4: Seek for maintenance.
Err13
Power output
phase loss
1: The cable between drive and motor is faulty.
2: The drive's three-phase output is unbalanced
when the motor is running.
3: The drive board is faulty
4: The IGBT is faulty.
1: Check the cable.
2: Check the motor windings.
3 to 4: Seek for maintenance.
Err14
IGBT overheat
1: The ambient temperature is too high.
2: The air filter is blocked.
3: The cooling fan is damaged.
4: The thermal sensor of IGBT is damaged.
5: The IGBT is damaged.
1: Lower the ambient temperature.
2: Clean the air filter.
3 to 5: Seek for maintenance.
Err15
External
equipment fault
1: External fault signal is input via DI.
2: External fault signal is input via virtual Input
terminal.
Reset.
Err16
Communication
fault
1: The host computer is abnormal.
2: The communication cable is faulty.
3: The communication parameters in group FD are
set improperly.
1: Check the cabling of host computer.
2: Check the communication cabling.
3: Set the communication parameters properly.
Err18
Current
detection fault
1: The HALL device is faulty.
2: The drive board is faulty.
Seek for maintenance.
Err21
EEPROM
read-write fault
The EEPROM chip is damaged.
Seek for maintenance.
Err26
Beyond the
accumulative
running time
limit
The accumulative running time reaches the setting
value F8-17.
Clear the record through the parameter initialization
function, set FP-01=2.
Err27
User-defined
fault 1
1: The user-defined fault 1 signal is input via DI.
2: User-defined fault 1 signal is input via virtual
terminal.
Reset.
efesotomasyon.com