Page 23 of 43
for times
1: Instantaneous power off.
2: The DC bus voltage is too low
ƿ
.
3: The rectifier bridge and buffer resistor are faulty.
4: The drive board is faulty.
5: The control board is faulty.
Check the power supply, or seek for maintenance.
1: Instantaneous power off.
2: The DC bus voltage is too low
ƿ
.
3: The rectifier bridge and buffer resistor are faulty.
4: The drive board is faulty.
5: The control board is faulty.
2: Check the DC bus.
3 to 6: Seek for maintenance.
1: The load is too heavy or the rotor is locked.
2: The drive is of too small power class.
1: Reduce the load, or check the motor, or check the
machine whether it is locking the rotor.
2: Select a drive of higher power class.
2: The load is too heavy or the rotor is locked.
3: The drive is of too small power class.
2: Reduce the load, or check the motor
machine whether it is locking the rotor.
3: Select a drive of larger power class.
phase loss
1: The three-phase power supply is abnormal.
2: The drive board is faulty.
3: The lightening protection board is faulty.
4: The control board is faulty.
1: Check the power supply.
2 to 4: Seek for maintenance.
phase loss
1: The cable between drive and motor is faulty.
2: The drive's three-phase output is unbalanced
when the motor is running.
3: The drive board is faulty
4: The IGBT is faulty.
2: Check the motor windings.
3 to 4: Seek for maintenance.
1: The ambient temperature is too high.
2: The air filter is blocked.
3: The cooling fan is damaged.
4: The thermal sensor of IGBT is damaged.
5: The IGBT is damaged.
1: Lower the ambient temperature.
2: Clean the air filter.
3 to 5: Seek for maintenance.
1: External fault signal is input via DI.
2: External fault signal is input via virtual Input
terminal.
fault
1: The host computer is abnormal.
2: The communication cable is faulty.
3: The communication parameters in group FD are
set improperly.
1: Check the cabling of host computer.
2: Check the communication cabling.
3: Set the communication parameters properly.
detection fault
1: The HALL device is faulty.
2: The drive board is faulty.
read-write fault
The EEPROM chip is damaged.
accumulative
running time
limit
The accumulative running time reaches the setting
value F8-17.
Clear the record through the parameter initialization
function, set FP-01=2.
fault 1
1: The user-defined fault 1 signal is input via DI.
2: User-defined fault 1 signal is input via virtual
terminal.