Page 2 of 43
1.3 General Specifications
ƹ
: Drives of 220 VAC power supply (both single-phase and three-phase) are being developed.
ƿ
: At 6 kHz carrier frequency without derating
ƾ
: Dimensions are shown as below:
:
$
%
+
'
2/ 2/
5.4 8.2 14.0 23.0 3.4 5.0 5.8 10.5 1.9 3.4 5.0 5.8
[kW] 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2
[HP] 0.5 1 2 3 0.5 1 2 3 0.5 1 2 3
2.3 4.0 7.0 9.6 2.1 3.8 5.1 9.0 1.5 2.1 3.8 5.1
1.0 1.5 3.0 4.0 1.0 3.0 4.0 5.9 1.2 1.5 3.0 4.0
[kW] ≥ 0.08 ≥ 0.08 ≥ 0.1 / ≥ 0.15 ≥ 0.15 ≥ 0.25 / ≥ 0.15 ≥ 0.15 ≥ 0.15 ≥ 0.25
[Ω] ≥ 200 ≥ 150 ≥ 100 / ≥ 150 ≥ 110 ≥ 100 / ≥ 300 ≥ 300 ≥ 220 ≥ 200
2
Dimension
Drive Input
Rated Input Voltage
Three-phase 380 to 440 VAC, -15 to 20%
(323 to 528 VAC)
Rated Input Current (A)
Rated Input Frequency 50/60 Hz, f5% (47.5 to 63 Hz)
Single-phase 220 VAC, -15 to 20%
(187 to 264 VAC)
Three-phase 220 VAC, -15 to 20%
(187 to 264 VAC)
Drive Output
Output Current, [A]
Power Capacity, [kVA]
Overload Capacity
120% for 1 hour & 150% for 60 Sec &180% for 2 Sec
Max. Output Voltage
Three-phase 380 VAC
(proportional to input voltage)
Fan Fan
Recommended
Braking Resistor
Cooling Method
Three-phase 220 VAC
(proportional to input voltage)
Three-phase 220 VAC
(proportional to input voltage)
Single-phase 220 VAC
Three-phase 220 VAC
Max. Output Frequency 500 Hz
Voltage Class
Drive Model
Frame Size 111
efesotomasyon.com