Function
Code
Parameter Name
Setting Range
Unit
Default
Commission
F4-37
DI3 delay time
0.0 to 3600.0
s
0.0
F4-38
DI active mode
selection
00000 to 11111
N.A. 00000
9 Group F5: Output Terminals
Function
Code
Parameter Name
Setting Range
Unit
Default
Commission
F5-02
Relay function
(T/A-T/B-T/C)
0 to 41
N.A. 2
F5-07
AO1 function selection
0 to 16
N.A.
0
F5-10
AO1 zero offset
coefficient
-100.0 to 100.0
%
0.0
F5-11
AO1 gain
-10.00 to10.00
N.A.
1.00
F5-18
Relay 1 output delay
time
0.0 to 3600.0
s 0.0
F5-22
DO active mode
selection
00000 to 11111
N.A. 00000
9 Group F6: Start/Stop Control
Function
Code
Parameter Name
Setting Range
Unit
Default
Commission
F6-00
Start mode
0: Direct startup
1: Reserved
2: Pre-excited startup (asynchronous motor)
N.A. 0
F6-03
Startup frequency
0.00 to 10.00
Hz
0.00
F6-04
Startup frequency
active time
0.0 to 100.0
s
0.0
F6-05
DC Injection Braking 1
level/
Pre-excitation level
0 to 100
%
0
F6-06
DC Injection Braking 1
active time/
Pre-excitation active
time
0.0 to 100.0
s
0.0
F6-07
Acceleration/
Deceleration mode
0: Linear mode
1: S-curve mode A
2: S-curve mode B
N.A. 0
F6-08
Time proportion of
S-curve start segment
0.0 to (100.0 minus F6-09)
%
30.0
F6-09
Time proportion of
S-curve end segment
0.0 to (100.0 minus F6-08)
% 30.0
F6-10
Stop mode
0: Decelerate to stop
1: Coast to stop
N.A.
0
F6-11
DC Injection Braking 2
frequency threshold
0.00 to Max. frequency
Hz
0.00
F6-12
DC Injection Braking 2
delay time
0.0 to 36.0
s 0.0
F6-13
DC Injection Braking 2
level
0 to 100
%
0
F6-14
DC Injection Braking 2
active time
0.0 to 36.0
s
0.0
F6-15
Braking use ratio
0 to 100
%
100