Page 6 of 43 
9  Terminals of Control Circuit 
-GND 
DC power supply 
Provide +10 VDC power supply to external unit. Usually, it provides power 
supply to external potentiometer with resistance range of 1kΩ
 to 5 kΩ. 
Max.. output current: 10 mA. 
-COM 
VDC power supply 
Provide +24 VDC power supply to external unit. Usually, it provides power 
supply to DI/DO terminals and external sensors
. 
Max. output current: 200 mA. 
 
Input terminal of external power supply
 
Connect to +24 VDC by default. Whether it connects to +24 V or COM is 
decided by jumper J3. 
When DI1 to 
DI5 need to be driven by external signal, 
OP needs to be connected to external power supply and be disconnected 
from +24 VDC. 
-GND 
 
Input voltage range: 0 to 10 VDC. 
Impedance: 22 kΩ. 
Optical coupling isolation, compatible with dual
-polarity input.   
4 kΩ. 
 to 30 VDC. 
-COM 
-speed pulse input 
Besides features of DI1 to DI4, it can be used for high-speed pulse input. 
Max. input frequency: 20 kHz. 
-GND 
 
 to 10 VDC. 
-485- 
 
MODBUS protocol.   
Baud rate: 300 to 115200 bps. 
 
 nodes: 32. 
Terminal resistance jumpers: J4 and J12. 
-T/B 
 
Contact driving capacity: 
250 
VAC, 0.2 A, COSø=0.4; 
VDC, 1 A. 
 
 
efesotomasyon.com