6. Description of Parameters
- 185 -
6
Function Code Parameter Name Setting Range Default
F5-17
FMR output delay
0.0s to 3600.0s
0.0s
F5-18
Relay 1 output delay
0.0s to 3600.0s
0.0s
F5-19
Relay 2 output delay
0.0s to 3600.0s
0.0s
F5-20
DO1 output delay
0.0s to 3600.0s
0.0s
F5-21
DO2 output delay
0.0s to 3600.0s
0.0s
These parameters set output delay of terminals FMR, relay1, relay2, DO1 and DO2 from state
change.
Function Code Parameter Name Setting Range Default
F5-22
DO active mode
selection 1
Relay1 active mode:
0: Positive logic active
1: Negative logic active
FMR active mode:
0: Positive logic active
1: Negative logic active
Relay2 active mode:
0: Positive logic active
1: Negative logic active
DO2 active mode:
0: Positive logic active
1: Negative logic active
DO1 active mode:
0: Positive logic active
1: Negative logic active
00000
This function parameter sets active mode of terminals FMR, relay1, relay2, DO1 and DO2.
Ɣ 0: Positive logic active
Digital output terminal becomes active when being connected with COM, and inactive when
being disconnected from COM.
Ɣ
1: Negative logic active
Digital output terminal becomes active when being disconnected from COM, and inactive
when being connected with COM.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD290T45G/55P and is the answer not in the manual?

Inovance MD290T45G/55P Specifications

General IconGeneral
BrandInovance
ModelMD290T45G/55P
CategoryDC Drives
LanguageEnglish

Related product manuals