Appendix
- 320 -
12
Para. No. Para. Name Setting Range Default Property Page
F8-28 Frequency detection value 2 0.00 Hz to max. frequency 50.00 Hz
ƿ
2
0
3
F8-29 Frequency detection hysteresis 2 0.0% to 100.0% 5.0%
ƿ
2
0
3
F8-30 Detection of frequency 1 0.00 Hz to max. frequency 50.00 Hz
ƿ
2
0
5
F8-31 Detection width of frequency 1 0.0% to 100.0% (max.
frequency)
0.0%
ƿ
2
0
5
F8-32 Detection of frequency 2 0.00 Hz to max. frequency 50.00 Hz
ƿ
2
0
5
F8-33 Detection width of frequency 2 0.0% to 100.0% (max.
frequency)
0.0%
ƿ
2
0
5
F8-34 Zero current detection level 0.0% to 300.0% (rated motor
current)
5.0%
ƿ
2
0
5
F8-35 Zero current detection delay 0.01s to 600.00s 0.10s
ƿ
2
0
5
F8-36 Output overcurrent threshold 0.0% (no detection)
0.1% to 300.0% (rated motor
current)
200.0%
ƿ
1
5
9
F8-37 Output overcurrent detection
delay
0.00s to 600.00s 0.00s
ƿ
1
5
9
F8-38 Detection level of current 1 0.0% to 300.0% (rated motor
current)
100.0%
ƿ
2
0
6
F8-39 Detection width of current 1 0.0% to 300.0% (rated motor
current)
0.0%
ƿ
2
0
6
F8-40 Detection level of current 2 0.0% to 300.0% (rated motor
current)
100.0%
ƿ
2
0
6
F8-41 Detection width of current 2 0.0% to 300.0% (rated motor
current)
0.0%
ƿ
2
0
6
F8-42 Timing function 0: Disabled
1: Enabled
0
ƾ
2
0
6
F8-43 Running time setting channel 0 to 3 0
ƾ
2
0
6
F8-44 Running time 0.0 to 6500.0 min 0.0 min
ƾ
2
0
6
F8-45 AI1 input voltage lower limit 0.00 V to F8-46 3.10 V
ƿ
2
0
7
F8-46 AI1 input voltage upper limit F8-45 to 10.00 V 6.80 V
ƿ
2
0
7
F8-47 IGBT temperature threshold 0°C to 100°C 75°C
ƿ
2
0
7
F8-48 Cooling fan working mode 0: Working during drive running
1: Working continuously
0
ƿ
2
0
7
F8-49 Wakeup frequency F8-51 to max. frequency (F0-
10)
0.00 Hz
ƿ
2
0
8
F8-50 Wakeup delay time 0.0s to 6500.0s 0.0s
ƿ
2
0
8
F8-51 Hibernating frequency 0.00 Hz to wakeup frequency
(F8-49)
0.00 Hz
ƿ
2
0
8
F8-52 Hibernating delay time 0.0s to 6500.0s 0.0s
ƿ
2
0
8
F8-53 Running time threshold this time 0.0 to 6500.0 min 0.0 min
ƿ
2
0
8
F8-54 Output power correction
FRHI¿FLHQW
0.0% to 200.0% 100.0%
ƿ
2
0
8
F8-55 Emergency stop time 0 to 6553.5 Model
dependent
ƿ
-