Appendix
- 332 -
12
Para. No. Para. Name Setting Range Default Property Page
A1-01 VDI2 function selection 16: Terminal 1 for acceleration/
deceleration time selection
17: Terminal 2 for acceleration/
deceleration time selection
18: Frequency reference setting
channel switchover
19: UP and DOWN setting clear
(terminal, operation panel)
20: Command source switchover 1
21: Acceleration/Deceleration
prohibited
22: PID disabled
23: PLC state reset
24: Wobble disabled
25: Counter input
26: Counter reset
27: Length signal pulses count
28: Length reset
30: Pulse input as frequency
reference (valid only for DI5)
31: Reserved
32: Immediate DC injection
braking
33: External fault normally-closed
input
)UHTXHQF\PRGL¿FDWLRQ
enabled
35: PID operation direction
reverse
36: External stop 1
37:
Command source switchover
2
38: PID integral disabled
39: Switchover between main
frequency reference and preset
frequency
40: Switchover between auxiliary
frequency reference and preset
frequency
41: Motor selection
42: Reserved
43: PID parameter switchover
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
47: Emergency stop (ES)
48: External stop 2
49: Deceleration DC injection
braking
50: Clear running time this time
51: Two-wire control/ Three-wire
control
52: Reverse running prohibited
53 to 59: Reserved
0
ƾ
1
8
6
A1-02 VDI3 function selection 0
ƾ
1
8
6
A1-03 VDI4 function selection 0
ƾ
1
8
6
A1-04 VDI5 function selection 0
ƾ
1
8
6