Appendix
- 339 -
12
Para. No. Para. Name Setting Range Default Property Page
Group A7: User Programmable Card
A7-00 User programmable function
selection
0: Disabled
1: Enabled
0
ƾ
1
7
3
A7-01 AC drive output terminal control
source selection
00000 to 11111
Relay (T/A-T/B-T/C):
0: AC drive control
1: User programmable card control
FMR (FM used as digital output):
0: AC drive control
1: User programmable card control
DO1:
0: AC drive control
1: User programmable card control
AO1:
0: AC drive control
1: User programmable card control
FMP (FM used as pulse output):
0: AC drive control
1: User programmable card control
00000
ƾ
1
7
4
A7-02 User programmable card AI3 and
AO2 function selection
0: AI3 (voltage input), AO2
(voltage output)
1: AI3 (voltage input), AO2
(current output)
2: AI3 (current input), AO2
(voltage output)
3: AI3 (current input), AO2
(current output)
4: AI3 (PTC input), AO2
(voltage output)
5: AI3 (PTC input), AO2
(current output)
6: AI3 (PT100 input), AO2
(voltage output)
7: AI3 (PT100 input), AO2
(current output)
0
ƾ
1
7
3
A7-03 PLC program controls the FMP
output
0.0% to 100.0% 0.0%
ƿ
1
7
4
A7-04 PLC program controls the AO1
output
0.0% to 100.0% 0.0%
ƿ
1
7
4
A7-05 Selection of PLC program
controlling digital output
000 to 111
Relay1
0: Disabled
1: Enabled
FMR
0: Disabled
1: Enabled
DO
0: Disabled
1: Enabled
000
ƿ
1
7
4
A7-06 Setting frequency reference via
the user programmable card
-100.00% to 100.00% 0.00%
ƿ
1
7
5