118
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
A9‑12 43276 Quick auto‑tuning of
asynchronous motor
stator resistance
before startup
0: Disabled
1: Enabled
0 Modifiable
in any states
A9‑13 43277 Quick asynchronous
motor stator
resistance auto‑tuning
coefficient 1
065535 10 Modifiable
only at stop
A9‑14 43278 Quick asynchronous
motor stator
resistance auto‑tuning
coefficient 2
065535 10 Modifiable
only at stop
A9‑15 43279 Quick asynchronous
motor stator
resistance auto‑tuning
coefficient 3
065535 0 Modifiable
only at stop
A9‑17 43281 Synchronous motor
real‑time angle
065535 0 Modification
prohibited
A9‑18 43282 Initial position angle
detection of
synchronous motor
0: Detected every running
1: Not detected
2: Detected upon initial
power‑on
0 Modifiable
in any states
A9‑20 43284 Field weakening mode 0: Automatic mode
1: Synchronous motor
adjustment mode
2: Synchronous motor
hybrid mode
3: Disabled
1 Modifiable
only at stop
A9‑21 43285 Field weakening gain
of synchronous motor
050 5 Modifiable
in any states
A9‑22 43286 Output voltage upper
limit margin of
synchronous motor
0% to 50% 5 % Modifiable
in any states
A9‑23 43287 Maximum force
adjustment gain of
synchronous motor
20% to 300% 100 % Modifiable
in any states
A9‑24 43288 Exciting current
adjustment gain
calculated by
synchronous motor
40% to 200% 100 % Modifiable
in any states
A9‑25 43289 Estimated
synchronous motor
speed integral gain in
SVC mode
51000 30 Modifiable
in any states